Spectrumlab透析夾 | SpectraPor® Tubing Closures/Universal Tubing Closures
Spectrum透析膜與化學溶液相溶性比較表 | Universal Closures 透析夾 | Spectra /Por®1-5 Standard | Spectra /Por® 6 Standard | 即用型透析管5ml | 微量即用型微量透析管 (400-500ul) | 中空纖維膜Hollow fiber filter | 透析夾 (Spectra/Por) | 透析夾之選擇
Universal透析夾適用各種透析膜,Speatra/Por僅適用於RC透析膜 →透析夾詳細資訊 使用時選用大於透析膜平寬(Flat Width, FW)4-10mm以上的透析夾來進行密封。RC膜專用型透析夾有標準、加重、磁力加重夾3種及二合一組合包裝(標準和加重),緊度較通用夾高並可高溫高壓滅菌處理。在選擇時,透析夾應比透析膜平面寬度再多4-10 mm,以確保透析夾能完全夾住透析袋密封。
CE膜或RC膜選擇 | 請先參閱 Spectrum透析膜與化學溶液相溶性比較表
Universal Closures 透析夾-RC膜及CE膜
通用透析管夾 (Universal Closures) 有用較溫和的密封凸緣,可適用於任何材質和厚度的透析膜 (包含RC膜跟CE膜),並擁有多種顏色,可用來區分不同的樣品。在選擇時,透析管夾應比透析管寬4-10 mm,以確保膜能夠完全達到緊密閉合的效果,使樣品不會外漏溢出。
![]()
| 功能特色 | 可適用於任何膜材的透析膜 |
| 膜種類 | 可用於Biotech CE, RC & PVDF; Standard RC |
| 4 種寬度 | 50 mm, 70 mm, 110 mm, 150 mm |
| 6 種顏色 | 白色, 紅色, 黃色, 綠色, 藍色, 黑色 |
| 包裝 | 10 ea /pkg |
| 材質 | Polyamide 6.6 from Dupont (Nylon) |
| 操作溫度 | 0 – 90°C (可滅菌) |
| 滅菌方式 | Gamma irradiation or ethylene oxide (not autoclavable) |
| Color | 50 mm | 70 mm | 110 mm | 150 mm | Qty |
| White | 142150 | 142170 | 142110 | 142250 | 10/pkg |
| Red | 142152 | 142172 | 142112 | 142252 | |
| Yellow | 142153 | 142173 | 142113 | 142253 | |
| Blue | 142154 | 142174 | – | – | |
| Green | 142155 | 142175 | – | – | |
| Black | 142156 | 142176 | – | – |
Spectra/Por Closures RC材質透析膜專用夾
此專用夾的夾力較大與緊密,因此適合RC材質的透析膜(軟與薄),並有輕巧的標準型夾一般可懸浮於透析液表面; 加重型可沉於透析液底部,與前者搭配可使透析膜垂直於透析液中,及磁力加重型透析夾含磁鐵可同時當磁石攪拌使用。

標準夾 (Standard Closure Type)
由於標準夾可漂浮,使用時夾於透析膜管上方增加浮力。可耐高溫高壓滅菌,並擁有多種顏色做區分。
| 功能特色 | 較輕可懸浮 |
| 膜種類 | 只能用在Standard RC membrane |
| 6 種寬度 | 12, 23, 35, 55, 75 & 90 mm |
| 4 種顏色 | 橘色, 白色, 綠色, 藍色 |
| 包裝 | 10 ea/pkg |
| 材質 | 聚丙烯 |
| 操作溫度 | 0 – 121°C (可滅菌) |
重量夾 (Weighted Closure Type)
可滅菌之重量夾含有以fluorocarbon 包覆表面的不鏽鋼棒。固定於透析膜管下方使固定透析膜管的垂直方向。
| 功能特色 | 加重重量以便下沉 |
| 膜種類 | 只能用在Standard RC membrane |
| 6 種寬度 | 12, 23, 35, 55, 75 & 90 mm |
| 1 種顏色 | 白色 |
| 包裝 | 10 ea/pkg |
| 材質 | 聚丙烯 |
| 操作溫度 | 0 – 121°C (可滅菌) |
磁力加重夾 (Magnetic Closure Type)
可滅菌之磁力加重夾含有以fluorocarbon 包覆表面的不鏽鋼棒,固定於透析膜管下方,可當作傳統的攪拌磁石
(stir bars)使用,因此在透析過程中無須而外再放入攪拌磁石。此方式透析膜會完全沉入透析液中,並將容器
置於磁力攪拌器 (stir plate) 上,利用溫和的轉速進行透析實驗。
| 功能特色 | 加重重量和磁力設計 |
| 膜種類 | 只能用在Standard RC membrane |
| 4 種寬度 | 23, 35, 55, 75 mm |
| 1 種顏色 | 紅色 |
| 包裝 | 2 ea/pkg |
| 材質 | 聚丙烯 |
| 操作溫度 | 0 – 121°C (可滅菌) |
標準夾和重量夾配對組 (Paired Standard & Weighted Closures)
利用標準夾和重量夾一上一下使用,使透析膜管達到浮起並垂直於透析液中,兩種透析夾均可進行滅菌處理。
| 功能特色 | 標準夾(浮力)&重量夾(加重量)兩者配合使透析膜管浮於透析液面並保持垂直 |
| 膜種類 | 只能用在Standard RC membrane |
| 6 種寬度 | 12, 23, 35, 55, 75 & 90 mm |
| 2 種顏色 | 橘色 (標準夾) & 白色 (重量夾) |
| 包裝 | 10 pairs/pkg |
| 材質 | 聚丙烯 |
| 操作溫度 | 0 – 121°C (可滅菌) |
| Closure Type | Color | Sealing Width | Qty | |||||
| 12 mm | 23 mm | 35 mm | 55 mm | 75 mm | 90 mm | |||
| 標準夾-Standard | Orange White Green Blue |
132734 142734 142834 142934 |
132735 142735 142835 142935 |
132736 142736 142837 142936 |
132737 142737 142837 142937 |
132738 142738 142838 142938 |
132739 142739 142839 142939 |
10/pkg |
| 重量夾-Weighted | White | 132742 | 132743 | 132744 | 132745 | 132746 | 132747 | 10/pkg |
| 標準夾&重量夾配對組 –Paired | Orange/White | 132749 | 132750 | 132751 | 132752 | 132753 | 132748 | 10 pairs |
| 磁力夾-Magnetic | Red | – | 132760 | 132762 | 132764 | 132766 | – | 2/pkg |
透析之原理介紹 | 如何選擇適合的分子量

利用分子會從高濃度擴散到低濃度,將待透析液放在具分子大小選擇性的透析膜中,進行物質交換。此時大分子的溶質會被保留,而小分子溶質會通過透析膜移除,最終達到去除的效果。一般而言,常規的透析需要進行2天的時間,才能達到透析的目的。而擴散係數(diffusion coefficients)、pH、溫度、時間、物質濃度、溶液體積、緩衝液體積,緩衝液更換次數、透析膜表面積、透析膜厚度,攪拌等因素都會影響到透析的效率。
MWCO是甚麼?
Molecular Weight Cut Off(MWCO)載留分子量是評估透析膜孔洞大小的單位。MWCO被定義為經過17小時透析後,保留90%以上的分子量大小。
選擇透析膜MWCO大小=欲保留分子量大小÷3。例如欲保留50KD以上物質,可選擇MWCO 20KD的透析膜。
![]()
![]()
如何進行透析:
將待透析品放入透析膜後,置入100X體積之緩衝液後開始進行透析。透析中至少進行三次緩衝液的換置,操作時間至少為16-24小時:
- 第一次:透析進行2-3小時後。
- 第一次:透析進行4-5小時後。
- 最後一次:overnight之前。
透析膜需要前處理嗎?
- Biotech RC、CE、與PVDF透析膜使用DI水清洗15-30分鐘(移除保存液sodium azide殘留)。
- Spectra/Por® 7 Standard RC透析膜已經過重金屬與硫化物去除的處理,只需要浸泡在DI水中15-30分鐘即可(移除保存液sodium azide殘留)。
- Spectra/Por 1-6 Standard RC透析膜,針對不同需求會有額外的處理手續。一般而言,可使用水清潔移除Spectra/Por 1-6 Standard RC透析膜中甘油的殘留。
CE膜或RC膜選擇 | 請先參閱Spectrum透析膜與化學溶液相溶性比較表
Standard Grade Regenerated Cellulose (RC) membrane 為透明、富有彈性的透析袋;擁有極高的化學耐受性,可承受低濃度的強酸強鹼溶液、高濃度的弱酸弱鹼溶液、多數醇類和稀釋的有機溶劑 (ex:DMSO),並可在承受 4-121 °C 和 pH 2-12 的環境下進行實驗;適用於將分子量差異大的樣品進行分離實驗,包含樣品製備、去除鹽類、置換緩衝溶液、調整pH值與蛋白質純化等。Spectra/Por ® 1 – 5 Standard RC Dialysis Tubing 為方便使用者保存,以乾燥的型式包裝出貨。一卷為 15 或 30 公尺,依需求自行裁切成合適的長度,對實驗需求量大者,是較為經濟型的包裝。大部分乾燥的透析袋在實驗前需浸泡過濾水30分鐘以去除保濕劑-glycerin。若乾燥的透析膜不帶有glycerin則只要稍做潤濕即可使用

| Membrane Type | Purpose | MWCO | 14 Flat Widths(mm) | Properties |
| Spectra/Por 1 | Basic dialysis | 6-8 kD | 10, 23, 32, 40, 50, 100, 120 | Standard RC with glycerol for general dialysis |
| Spectra/Por 2 | Higher permeability | 12-14 kD | 10, 25, 45, 105, 120 | Standard RC with glycerol in multiple configurations |
| Spectra/Por 3 | Basic dialysis | 3.5 kD | 18, 45, 54 | Standard RC with or without glycerol for general dialysis |
| Spectra/Por 4 | Basic dialysis | 12-14 kD | 10, 25, 32, 45, 75 | Standard RC with glycerol for general dialysis |
| Spectra/Por 5 | Reinforced for weight | 12 – 14 kD | 75, 140 | Standard RC without glycerol, reinforced with porous fiber for large volume and weight |
| Properties: | Hydrophilic, symmetric porosity | |||
| Quantity: | 15 or 30 m roll (depending on Type and Flat Width) | |||
| Packaging: | Dry with Glycerin (soak in water) or Dry without Glycerin (no soaking required) | |||
Spectra/Por 6和7預潤濕型透析袋,只需泡水去除sodium azide即可使用;7號比6號的重金屬與硫化物含量更低;兩者皆有經濟包組(含透析夾)供條件測試與小量使用。相較於Spectra/Por ® 1 – 5 Standard RC Dialysis Tubing乾燥形式包裝,6和7號已濕潤處理並浸泡在0.05% sodium azide抗菌保存,使用前只需稍微使用二次水清洗即可使用。

|
Spectra/Por® 6:
|
Pre-wetted
|
|
8 MWCO’s:
|
1 kD, 2 kD, 3.5 kD, 8 kD, 10 kD, 15 kD, 25 kD & 50 kD
|
|
13 Flat Widths:
|
8 mm, 10mm, 12 mm, 18 mm, 24 mm, 28 mm, 32 mm, 34 mm, 38 mm, 40 mm, 45 mm, 50 mm & 54 mm
|
|
Qty & Pkg:
|
10 m roll, wet in 0.05% sodium azide
|
|
Spectra/Por® 7:
|
Pre-treated to reduce trace-level contaminants
|
|
8 MWCO’s:
|
1 kD, 2 kD, 3.5 kD, 8 kD, 10 kD, 15 kD, 25 kD & 50 kD
|
|
12 Flat Widths:
|
8 mm, 12 mm, 18 mm, 24 mm, 28 mm, 32 mm, 34 mm, 38 mm, 40 mm, 45 mm, 50 mm & 54 mm
|
|
Qty & Pkg:
|
5 m roll, wet in 0.05% sodium azide |
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
透析袋需搭配透析夾使用,請參考: 透析夾RC膜專用型 Spectra/Por Closure或透析夾通用型 Universal Closur
Biotech Grade Dialysis Membranes & Trial Kits
超純生物等級透析袋,不含重金屬、硫化物與雜質;具有精確的截留分子量和極佳的樣品回收率;過濾水浸泡潤濕後即可使用;兩種材質選擇:1.Cellulose ester(CE):較多截留分子量選擇 2.Regenerated cellulose(RC):較高的溫度、pH值與化學耐受材質。
| MWCO | FW: | 10 mm | 16 mm | 24 mm | 31 mm | |
| Dia: | 6.4 mm | 10 mm | 16 mm | 20 mm | ||
| Vol: | 0.32 mL/cm | 0.79 mL/cm | 1.8 mL/cm | 3.1 mL/cm | ||
| CE tubing (10 m/roll) |
0.1-0.5 KD | 131048 | 131054 | 131057 | 131060 | |
| 0.5-1.0 KD | 131084 | 131090 | 131093 | 131096 | ||
| 3.5-5 KD | 131192 | 131198 | 131201 | 131204 | ||
| 8-10 KD | 131264 | 131270 | 131273 | 131276 | ||
| 20 KD | 131336 | 131342 | 131345 | 131348 | ||
| 50 KD | 131372 | 131378 | 131381 | 131384 | ||
| 100 KD | 131408 | 131414 | 131417 | 131420 | ||
| 300 KD | – | 131450 | – | 131456 | ||
| 1000 KD | – | 131486 | – | 131492 | ||
| RC tubing (5 m/roll) |
3.5-5 KD | 133192 | 133198 | |||
| 8-10 KD | 133264 | 133270 | ||||
| 20 KD | 133336 | 133342 |
NEW! Biotech CE Dialysis Trial Kits
Ideal for small tubing demand applications or evaluating a specific dialysis membrane, the Trial Kit provides 1 meter of tubing with a pair of tubing closures and 5 opening picks.

| MWCO | FW: | 10 mm | 16 mm | 24 mm | 31 mm | |
| Dia: | 6.4 mm | 10 mm | 16 mm | 20 mm | ||
| Vol: | 0.32 mL/cm | 0.79 mL/cm | 1.8 mL/cm | 3.1 mL/cm | ||
| CE trial kit (1 m/roll) |
0.1-0.5 KD | 131048T | 131054T | 131057T | 131060T | |
| 0.5-1.0 KD | 131084T | 131090T | 131093T | 131096T | ||
| 3.5-5 KD | 131192T | 131198T | 131201T | 131204T | ||
| 8-10 KD | 131264T | 131270T | 131273T | 131276T | ||
| 20 KD | 131336T | 131342T | 131345T | 131348T | ||
| 50 KD | 131372T | 131378T | 131381T | 131384T | ||
| 100 KD | 131408T | 131414T | 131417T | 131420T | ||
| 300 KD | – | 131450T | – | 131456T | ||
| 1000 KD | – | 131486T | – | 131492T | ||
| RC trial kit (0.5 m/roll) |
3.5-5 KD | 133192T | 133198T | |||
| 8-10 KD | 133264T | 133270T | ||||
| 20 KD | 133336T | 133342T |
透析膜長度
全長=[(樣品容量)/(體積/長度比)]+(額外的10-20%)+4 cm →計算您要使用多長的透析膜例如:透析膜平寬(FW)為16 mm,體積/長度比為0.79 ml/cm。欲透析5 ml樣品,則至少需約6.5 cm透析膜。但還需要額外的10-20%的長度(至少1 cm)使透析管填充空氣維持浮力。最後還需要頭尾各2 cm給透析夾使用。整個透析膜長至少需要11.5 cm長。