{"id":45689,"date":"2023-09-06T16:05:07","date_gmt":"2023-09-06T08:05:07","guid":{"rendered":"https:\/\/biopioneer.com.tw\/?p=45689"},"modified":"2023-10-22T12:13:26","modified_gmt":"2023-10-22T04:13:26","slug":"%e8%a1%80%e7%b4%85%e8%9b%8b%e7%99%bd%e6%b8%ac%e5%ae%9a%e8%a9%a6%e5%8a%91%e7%9b%92-hemoglobin-assay-kit-%e8%b2%a8%e8%99%9fabnova-ka1616","status":"publish","type":"post","link":"https:\/\/biopioneer.com.tw\/?p=45689","title":{"rendered":"\u8840\u7d05\u86cb\u767d\u6e2c\u5b9a\u8a66\u5291\u76d2| Hemoglobin Assay Kit \u8ca8\u865fAbnova\u2122 KA1616"},"content":{"rendered":"<p><span style=\"color: #33cccc; font-size: 12pt;\"><strong><a style=\"color: #33cccc;\" href=\"https:\/\/biopioneer.com.tw\/?p=45689&amp;preview=true\"><span style=\"font-size: 12pt;\">\u8840\u7d05\u86cb\u767d\u6e2c\u5b9a\u8a66\u5291\u76d2| Hemoglobin Assay Kit \u8ca8\u865fAbnova\u2122 KA1616<\/span><\/a><\/strong><\/span><\/p>\n<p><img decoding=\"async\" loading=\"lazy\" class=\"\" src=\"https:\/\/biopioneer.com.tw\/wp-content\/uploads\/downloads\/2023\/08\/abnova.png\" width=\"628\" height=\"82\" \/><\/p>\n<p><span style=\"color: #999999;\">\u9748\u654f\u5ea60.9 to 200 mg\/dL hemoglobin in 96-well plate assay. 250 assays (In 96-well plates)<\/span><\/p>\n<p>\u8840\u7d05\u86cb\u767d (Hemoglobin , Hb) \u7531\u56db\u500b\u73e0\u86cb\u767d\u93c8(globin chains )\u7d44\u6210\uff0c\u6bcf\u500b\u73e0\u86cb\u767d\u93c8\u651c\u5e36\u4e00\u500b\u8840\u7d05\u7d20\u57fa\u5718(red blood cells)\u3002\u5b83\u7531\u7d05\u7d30\u80de\u651c\u5e36\uff0c\u5c07\u6c27\u6c23\u5f9e\u80ba\u90e8\u8f38\u9001\u5230\u5468\u570d\u7d44\u7e54\uff0c\u4ee5\u7dad\u6301\u7d30\u80de\u7684\u6d3b\u529b\u3002\u8840\u6db2\u4e2d\u8840\u7d05\u86cb\u767d\u7684\u5b9a\u91cf\u5df2\u6210\u70ba\u591a\u7a2e\u75be\u75c5\u7684\u95dc\u9375\u8a3a\u65b7\u53c3\u6578\uff0c\u4f8b\u5982\u8ca7\u8840(anemia)\u3001\u7d05\u8840\u7403\u589e\u591a\u75c7(polycythemia)\u548c\u812b\u6c34(dehydration)\u3002\u7528\u65bc\u6e2c\u91cf\u8840\u7d05\u86cb\u767d\u6fc3\u5ea6\u7684\u7c21\u55ae\u3001\u76f4\u63a5\u548c\u81ea\u52d5\u5316\u7a0b\u5e8f\u5728\u7814\u7a76\u548c\u85e5\u7269\u767c\u73fe(Drug Discovery)\u4e2d\u8b8a\u5f97\u8d8a\u4f86\u8d8a\u6d41\u884c\u3002\u8840\u7d05\u86cb\u767d\u6aa2\u6e2c\u8a66\u5291\u76d2(The Hemoglobin Assay Kit)\u57fa\u65bc\u6539\u9032\u7684\u9e7c\u6027\u6c34\u6eb6\u6db2\u65b9\u6cd5( improved aqueous alkaline method)\uff0c\u5176\u4e2d\u8840\u7d05\u86cb\u767d(hemoglobin)<strong>\u662f<\/strong>\u8f49\u5316\u70ba\u984f\u8272\u5747\u52fb\u7684\u6700\u7d42\u7522\u54c1\u3002\u5728 400 nm \u8655\u6e2c\u91cf\u7684\u984f\u8272\u5f37\u5ea6\u53ef\u76f4\u63a5\u8207\u6a23\u54c1\u4e2d\u7684\u8840\u7d05\u86cb\u767d\u6fc3\u5ea6\u6210\u6b63\u6bd4\u3002\u512a\u5316\u7684\u914d\u65b9\u5177\u6709\u9ad8\u9748\u654f\u5ea6\u548c\u975e\u5e38\u9069\u5408\u6e2c\u91cf\u4f4e\u8840\u7d05\u86cb\u767d\u6a23\u54c1\uff08\u4f8b\u5982\u8840\u6e05\u548c\u8840\u6f3f\uff09\u4e2d\u7684\u6eb6\u8840\u60c5\u6cc1\u3002<\/p>\n<p>\u2713 \u76f4\u63a5\u6aa2\u6e2c\uff1a\u8840\u6e05\u3001\u8840\u6f3f\u3001\u5c3f\u6db2\u7b49\u4e2d\u7684\u7e3d\u8840\u7d05\u86cb\u767d\u3002<\/p>\n<p>\u2713 \u85e5\u7406\u5b78\uff1a\u85e5\u7269\u5c0d\u8840\u7d05\u86cb\u767d\u4ee3\u8b1d\u7684\u5f71\u97ff\u3002<\/p>\n<p>\u2713 \u85e5\u7269\u767c\u73fe\uff1a\u8abf\u7bc0\u8840\u7d05\u86cb\u767d\u6c34\u5e73\u7684\u85e5\u7269\u7684 HTS\u3002<\/p>\n<p>\u2713 \u9748\u654f\u4e14\u6e96\u78ba\uff1a96 \u5b54\u677f\u6e2c\u5b9a\u4e2d\u8840\u7d05\u86cb\u767d\u7684\u7dda\u6027\u6aa2\u6e2c\u7bc4\u570d\u70ba 0.9 \u2013 200 mg \/dL\u3002<br \/>\n\u2713 \u7c21\u55ae\u4e14\u9ad8\u901a\u91cf\uff1a\u201c\u6df7\u5408\u8b80\u53d6\u201d\u7a0b\u5e8f\u6d89\u53ca\u6dfb\u52a0\u55ae\u4e00\u5de5\u4f5c\u8a66\u5291 \u4e26\u8b80\u53d6\u5149\u5bc6\u5ea6\u3002\u53ef\u4ee5\u5728 96 \u5b54\u677f\u4e2d\u8f15\u9b06\u5be6\u73fe\u81ea\u52d5\u5316\u9ad8\u901a\u91cf\u6aa2\u6e2c\u6bcf\u5929\u53ef\u8655\u7406\u6578\u5343\u500b\u6a23\u54c1\u3002<br \/>\n\u2713 \u5b89\u5168\uff1a\u8a66\u5291\u7121\u6bd2\u3002<br \/>\n\u2713 \u591a\u529f\u80fd\u6027\uff1a\u53ef\u5728 96 \u5b54\u677f\u6216\u6bd4\u8272\u76bf\u4e2d\u9032\u884c\u6e2c\u5b9a<\/p>\n<pre id=\"tw-target-text\" class=\"tw-data-text tw-text-large tw-ta\" dir=\"ltr\" data-placeholder=\"\u7ffb\u8b6f\"><\/pre>\n<p><a href=\"http:\/\/biopioneer.com.tw\/wp-content\/uploads\/downloads\/2023\/09\/1-\u8840\u7d05\u86cb\u767d\u6e2c\u5b9a\u8a66\u5291\u76d2-Hemoglobin-Assay-Kit-\u8ca8\u865fAbnova\u2122-KA1616.pdf\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone\" src=\"http:\/\/biopioneer.com.tw\/wp-content\/uploads\/2023\/01\/%E7%B6%B2%E7%AB%99%E8%A6%8F%E6%A0%BC%E5%B0%8F%E5%9C%96_%E5%B7%A5%E4%BD%9C%E5%8D%80%E5%9F%9F-1_%E5%B7%A5%E4%BD%9C%E5%8D%80%E5%9F%9F-11-300x97.jpg\" alt=\"\u7db2\u7ad9\u898f\u683c\u5c0f\u5716_\u5de5\u4f5c\u5340\u57df 1_\u5de5\u4f5c\u5340\u57df 1\" width=\"149\" height=\"48\" \/><\/a><\/p>\n<p><span style=\"color: #993366;\"><strong><span style=\"font-size: 12pt;\">\u6a23\u54c1\u88fd\u5099 (Sample Preparation)<br \/>\n<\/span><\/strong><\/span>Samples. Serum and plasma samples can be assayed directly (n = 1).<\/p>\n<p><b style=\"color: #800000;\">Specification<br \/>\n<\/b><\/p>\n<div id=\"400000\">\n<div id=\"400000\">\n<div id=\"10000\">\n<ul>\n<li class=\"black12 sub_title\"><b>Product Description:<\/b><\/li>\n<li class=\"black11_a_underline sub_content\">Hemoglobin Assay Kit is a colorimetric determination of total hemoglobin at 400 nm.<\/li>\n<\/ul>\n<\/div>\n<div id=\"10100\">\n<ul>\n<li class=\"black12 sub_title\"><b>Suitable Sample:<\/b><\/li>\n<li class=\"black11_a_underline sub_content\">Plasma, Serum, Urine<\/li>\n<\/ul>\n<\/div>\n<div id=\"10200\">\n<ul>\n<li class=\"black12 sub_title\"><b>Sample Volume:<\/b><\/li>\n<li class=\"black11_a_underline sub_content\">50 uL (using 96-well plate)<br \/>\n100 uL (using cuvette)<\/li>\n<\/ul>\n<\/div>\n<div id=\"10400\">\n<ul>\n<li class=\"black12 sub_title\"><b>Detection Method:<\/b><\/li>\n<li class=\"black11_a_underline sub_content\">Colorimetric<\/li>\n<\/ul>\n<\/div>\n<div id=\"20000\">\n<ul>\n<li class=\"black12 sub_title\"><b>Calibration Range:<\/b><\/li>\n<li class=\"black11_a_underline sub_content\">0.9 to 200 mg\/dL hemoglobin in 96-well plate assay.<\/li>\n<\/ul>\n<\/div>\n<div id=\"260100\">\n<ul>\n<li class=\"black12 sub_title\"><b>Regulation Status:<\/b><\/li>\n<li class=\"black11_a_underline sub_content\">For research use only (RUO)<\/li>\n<\/ul>\n<\/div>\n<div id=\"290000\">\n<ul>\n<li class=\"black12 sub_title\"><b>Quality Control Testing:<\/b><\/li>\n<li class=\"black11_a_underline sub_content\">Standard Curve<br \/>\n<b><\/b><br \/>\n<img decoding=\"async\" title=\"QC Testing of KA1616\" src=\"https:\/\/www.abnova.com\/qc_test_image\/qc_test-KA1616-1.jpg\" alt=\"QC Testing of KA1616\" \/><br \/>\nThe standard curve is for the purpose of illustration only and should not be used to calculate unknowns. A standard curve should be generated each time the assay is performed.<\/li>\n<\/ul>\n<\/div>\n<div id=\"400000\">\n<ul>\n<li class=\"black12 sub_title\"><b>Storage Instruction:<\/b><\/li>\n<li class=\"black11_a_underline sub_content\">Store the kit at 4\u00b0C.<\/li>\n<\/ul>\n<\/div>\n<\/div>\n<\/div>\n<p><span style=\"font-size: 12pt; color: #800000;\"><b>Publication Reference<\/b><\/span><\/p>\n<p>1.<a href=\"http:\/\/www.ncbi.nlm.nih.gov\/pubmed\/26846855\" target=\"_new\" rel=\"noopener\">Oxygen-dependent Regulation of Erythropoietin Receptor Turnover and Signaling.<\/a><br \/>\nHeir P, Srikumar T, Bikopoulos G, Bunda S, Poon BP, Lee JE, Raught B, Ohh M.J Biol Chem. 2016 Apr 1;291(14):7357-72.<\/p>\n<p>2.<a href=\"http:\/\/www.ncbi.nlm.nih.gov\/pubmed\/?term=25988285\" target=\"_new\" rel=\"noopener\">When blood transfusion medicine becomes complicated due to interference by monoclonal antibody therapy.<\/a><br \/>\nOostendorp M, Lammerts van Bueren JJ, Doshi P, Khan I, Ahmadi T, Parren PW, van Solinge WW, De Vooght KM.Transfusion. 2015 May 18.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/biopioneer.com.tw\/wp-content\/uploads\/downloads\/2023\/09\/%E8%A1%80%E7%B4%85%E8%9B%8B%E7%99%BD%E6%B8%AC%E5%AE%9A%E8%A9%A6%E5%8A%91%E7%9B%92-Hemoglobin-Assay-Kit-%E8%B2%A8%E8%99%9FAbnova%E2%84%A2-KA1616.png\" \/><\/p>\n","protected":false},"excerpt":{"rendered":"<p>\u8840\u7d05\u86cb\u767d\u6e2c\u5b9a\u8a66\u5291\u76d2| Hemoglobin Assay Kit \u8ca8\u865fAbnova\u2122 KA1616 \u9748\u654f\u5ea60.9 [&hellip;]<\/p>\n","protected":false},"author":3,"featured_media":40950,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":[],"categories":[5549],"tags":[6162],"_links":{"self":[{"href":"https:\/\/biopioneer.com.tw\/index.php?rest_route=\/wp\/v2\/posts\/45689"}],"collection":[{"href":"https:\/\/biopioneer.com.tw\/index.php?rest_route=\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/biopioneer.com.tw\/index.php?rest_route=\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/biopioneer.com.tw\/index.php?rest_route=\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/biopioneer.com.tw\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=45689"}],"version-history":[{"count":1,"href":"https:\/\/biopioneer.com.tw\/index.php?rest_route=\/wp\/v2\/posts\/45689\/revisions"}],"predecessor-version":[{"id":45690,"href":"https:\/\/biopioneer.com.tw\/index.php?rest_route=\/wp\/v2\/posts\/45689\/revisions\/45690"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/biopioneer.com.tw\/index.php?rest_route=\/wp\/v2\/media\/40950"}],"wp:attachment":[{"href":"https:\/\/biopioneer.com.tw\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=45689"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/biopioneer.com.tw\/index.php?rest_route=%2Fwp%2Fv2%2Fcategories&post=45689"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/biopioneer.com.tw\/index.php?rest_route=%2Fwp%2Fv2%2Ftags&post=45689"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}